Installation instructions for ground-mounted panels
Please contact us if you need more information about the installation instructions.
Emailinfo@pordran.se or call08 607 32 60
Dimensioning tables
Earth pressure in clay soils
Clay soils come in various clay content levels. This table refers to clay soils with a density of up to 17 kN/m³ and a shear strength of 15 kPa at the critical point. If you are unsure, always choose a panel with a higher value and consult a geotechnical specialist.
| Excavation depth | Pordrän mat |
|---|---|
| 0–2.5 m | P19 | P25 | P30 | P35 | P45 | P55 |
| 2.5–3.0 m | P25 | P30 | P35 | P45 | P55 |
| 3.0–3.5 m | P30 | P35 | P45 | P55 |
| 3.5–4.0 m | P35 | P45 | P55 |
| 4.0–5.5 m | P45 | P55 |
| 5.5–7.0 m | P55 |
Earth pressure in sandy and gravelly soils
Sand and gravel soils are included. This table refers to soils with a density of up to 19 kN/m³ and a friction angle of ka = 0.31. If you are unsure, always choose a plate with a higher value and consult a geotechnical specialist.
| Excavation depth | Pordrän mat |
|---|---|
| 0–2.5 m | P19 | P25 | P30 | P35 | P45 | P55 |
| 2.5–3.0 m | P25 | P30 | P35 | P45 | P55 |
| 3.0–3.5 m | P30 | P35 | P45 | P55 |
| 3.5–4.0 m | P35 | P45 | P55 |
| 4.0–5.5 m | P45 | P55 |
| 5.5–7.0 m | P55 |
Vertical load
Here you can select Pordrän for various roof and ground projects based on vertical loads.
The design specifications are based on our own experience as well as the Swedish National Board of Housing, Building and Planning’s design rules EKS 11 and the Eurocode Handbook EKS6,an excerptof which you canreadhere.
Grass areas for physical activities
For example, soccer fields. Live load according to load group C4 (≤ 4 kN/m²).
| Building height | Pordrän mat |
|---|---|
| 100, 200, 300, and 400 mm | P19 | P25 | P30 | P35 | P45 | P55 |
Surfaces with tiles or gravel areas for physical activities
For example, soccer fields or terraces. Live load according to load group C4 (≤ 4 kN/m²).
| Building height | Pordrän mat |
|---|---|
| 100 mm & 200 mm | P30 | P35 | P45 | P55 |
| 300 mm & 400 mm | P25 | P30 | P35 | P45 | P55 |
Lanes for emergency vehicles, small trucks, and work vehicles
70% of the load group according to Figure C-1b in the Swedish National Board of Housing, Building and Planning’s design regulations, EKS 11.
| Building height | Pordrän mat |
|---|---|
| 150 mm | P55 |
| 200 mm | P45 | P55 |
| 300 mm & 400 mm | P25 | P30 | P35 | P45 | P55 |
Driving lanes and parking for light vehicles
Examples: Parking spaces, access roads, loading zones.
Applies to vehicles with a gross weight ≤ 30 kN and ≤ 8 seats excluding the driver’s seat (load according to Eurocode 1991-1-1, Category F).
| Building height | Pordrän mat |
|---|---|
| 150 mm | P45 | P55 |
| 200 mm, 300 mm, and 400 mm | P25 | P30 | P35 | P45 | P55 |
Driving lanes and parking for medium-duty vehicles
Examples: Parking spaces, access roads, loading zones.
Applies to vehicles with a gross weight of ≤ 160 kN on two axles (load according to Eurocode 1991-1-1, Category G).
| Building height | Pordrän mat |
|---|---|
| 200 mm | P55 |
| 300 mm | P35 | P45 | P55 |
| 400 mm | P25 | P30 | P35 | P45 | P55 |
The assembly instructions will appear here.